| ONLINE UPS |
|
|
|
|
| Product Mode: C6K/C6KS, C10K/C10KS |
| |
 |
| |
| APPLICATION: |
| Servers, Data centers, Critical network devices, Sensitive electronic equipment, Telecom... |
| |
KEY FEATURES: |
-True online double conversion technology
- Wide input voltage range
- Zero transfer time
- Protection against all types of power problems
- No add-on CNTL unit required for parallel connection
- Low initial investment and flexible for future expansion
- Highest reliability and maximum performance for power sharing and redundancy
- Equipped with Maintenance Bypass Switch
- Smart RS232 and Intelligent slot interface
- Sealed lead-acid, maintenance free battery |
| |
TECHNICAL SPECIFICATIONS£º |
Model |
C6K |
C10K |
Rated Power |
VA/W |
6kVA/4.2kW |
10kVA/7kW |
Input |
Nominal Voltage |
220VAC |
VoltageRange |
176 ~ 276VAC |
FrequencyRange |
46 ~ 54Hz |
Power Factor |
0.98 |
Connection |
Hardwired |
Output |
Voltage |
220VAC ¡À1% |
Frequency |
50Hz ¡À0.1% (Batterymode) |
Waveform |
Sine Wave |
Power factor |
0.7 |
Voltage Distortion |
2% under linear load |
Overload Capability |
105% ~ 130% for 10 min., 3130% for 1 min. |
Current Crest Ratio |
3:1 max. |
Connection |
Hardwired |
Battery |
Type |
Sealed, Maintenance free, Lead-Acid |
Quantity |
20 pieces |
Back-up time (full load) |
7 min |
5 min |
Recharge time |
8 hrs to 90% of capacity after full load discharge |
Transfer time |
0 ms |
Maintenance Bypass Switch |
Yes |
LED indicators |
Status |
Load level/Battery level, Battery, Utility power, Inverter, Bypass, Overload, Fault |
Audible alarm |
Bypass |
Alarm beeps every two minutes |
Batterydischarge |
Alarm beeps every four seconds, every second if battery low |
Overload |
Alarm beeps two for every second |
Fault |
Alarm beeps continuously |
Acoustic noise |
At 1 meter distance |
¡ê 55 dBA |
Communications |
DB-9 Port |
RS232 serial interface |
Intelligent Slot |
Options: WebPower, AS400 or WinPower CMC |
ParallelPort |
up to three units in parallel for power redundancy and load sharing |
Environmental |
Operating temperature |
0 ~ 40¡ãC |
Operating humidity |
20% ~ 90% non-condensing |
Weight |
Net (kg) |
84 |
93 |
Dimensions |
W x D x H (mm) |
260 x 570 x 717 |
|
| |
Model |
C6KS |
C10KS |
Rated Power |
Volt-Amps/Watts (VA/W) |
6kVA/4.2kW |
10kVA/7kW |
Input |
Nominal Voltage |
220VAC |
VoltageRange |
176 ~ 276VAC |
FrequencyRange |
46 ~ 54Hz |
Power Factor |
0.98 |
Connection |
Hardwired |
Output |
Voltage |
220VAC ¡À1% |
Frequency |
50Hz ¡À0.1% (Batterymode) |
Waveform |
Sine Wave |
Power factor |
0.7 |
Voltage Distortion |
2% under linear load |
Overload Capability |
105% ~ 130% for 10 min., 3130% for 1 min. |
Current Crest Ratio |
3:1 max. |
Connection |
Hardwired |
Battery |
Type |
Sealed, Maintenance free, Lead-Acid |
Nominal DC Voltage |
240VDC |
Back-up time |
Depends on the capacity of the external battery bank |
Connection |
External BatterySocket |
Transfer time |
0 ms |
Maintenance Bypass Switch |
Yes |
LED indicators |
Status |
Load level/Battery level, Battery, Utility power, Inverter, Bypass, Overload, Fault |
Audible alarm |
Bypass |
Alarm beeps every two minutes |
Batterydischarge |
Alarm beeps every four seconds, every second if battery low |
Overload |
Alarm beeps two for every second |
Fault |
Alarm beeps continuously |
Acoustic noise |
At 1 meter distance |
¡ê 55 dBA |
Communications |
DB-9 Port |
RS232 serial interface |
Intelligent Slot |
Options: WebPower, AS400 or WinPower CMC |
ParallelPort |
up to three units in parallel for power redundancy and load sharing |
Environmental |
Operating temperature |
0 ~ 40¡ãC |
Operating humidity |
20% ~ 90% non-condensing |
Weight |
Net (kg) |
35 |
38 |
Dimensions |
W x D x H (mm) |
260 x 570 x 717 |
|
| Please consult the factory or the distributors for further information of ¡°S¡± models. |
Specifications are subject to change without notice |
|
|